9 Series Fire

QT EcoSeries Wall Panel FRL 60/60/60
(AS-11.1.1.A)

Note
Direct fixed or battened out cavity will not alter the fire resistance level of this wall.

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

QT EcoSeries Wall Panel FRL 90/90/90
(AS-11.1.2.A)

Note
Direct fixed or battened out cavity will not alter the fire resistance level of this wall.

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

Fire Rated Vertical Control Joint
(AS-11.2.1.B)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

Fire Rated Horizontal Control Joint
(AS-11.2.2B)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

find out more