Warning: include(http://klahost.com/floating-banner/melbourne.php): failed to open stream: HTTP request failed! HTTP/1.1 404 Not Found in /home/qtaustra/public_html/wp-content/themes/breezing/header.php on line 83

Warning: include(): Failed opening 'http://klahost.com/floating-banner/melbourne.php' for inclusion (include_path='.:/opt/php54/lib/php') in /home/qtaustra/public_html/wp-content/themes/breezing/header.php on line 83

QT Eco Series

post by | | 0

3 Series Window

Window Head Type 1 (AS-5.36.B)

Window Sill Type 1 (AS-5.1.B)

Window Head Type 2 (AS-5.6.B)

Window Sill Type 2 (AS-5.4.B)

Window Jamb – Type 1 (AS-5.2.B)

Window Jamb – Type 2 (AS-5.5.B)

Window Sill Type 3 (AS-5.7.B)

Note

All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

find out more

post by | | 0

4 Series Soffit

Soffit Type 1
(AS-6.1.B)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

Soffit Type 2
(AS-6.2.B)

Flush Eaves
(AS-6.3.B)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

find out more

post by | | 0

5 Series Doors

Roller Door Jamb
(AS-7.2.B)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

Sliding Door
Door Head (AS-7.5.B)

find out more

post by | | 0

6 Series Walto Roof

Wall to Roof – Type 1
(AS-8.1.B)

Wall to Roof – Type 2
(AS-8.2.B)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

Wall Plates for Pergolas – Type 1
(AS-8.3.A)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

find out more

post by | | 0

7 Series Parapet

Balustrade Exposed Type 1
(AS-9.2.A)

Balustrade Exposed Type 1
(AS-9.2.A)

Parapet Type 1
(AS-9.3.B)

Parapet Type 2
(AS-9.4.B)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

Balustrade to Wall Junction Detail
(AS-9.5.A)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

Parapet Type 3
(AS-9.7.A)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

find out more

post by | | 0

8 Series Deck

Deck or patio Detail
(AS-10.1.B)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

Wall Plate to Pergola Detail – Type 1
(AS-10.2.A)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

find out more

post by | | 0

9 Series Fire

QT EcoSeries Wall Panel FRL 60/60/60
(AS-11.1.1.A)

Note
Direct fixed or battened out cavity will not alter the fire resistance level of this wall.

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

QT EcoSeries Wall Panel FRL 90/90/90
(AS-11.1.2.A)

Note
Direct fixed or battened out cavity will not alter the fire resistance level of this wall.

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

Fire Rated Vertical Control Joint
(AS-11.2.1.B)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

Fire Rated Horizontal Control Joint
(AS-11.2.2B)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

find out more

post by | | 0

10 Series Misc

Pipe Penetration Through Conpolcrete®
(AS-12.2.A)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

Typical Meter Board Fixing Detail
(AS-12.5.B)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

Typical Downpipe Fixing Detail
(AS-12.6.A)

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT Buttons at 225mm centres as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.

find out more